APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord

SKU
AP8886
$3,211.67
In stock
Only 7 left
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
Estimate Fees
For corporate price, please request for quotation at sales@techfable.com.au
More Information
SKU AP8886
EAN 0731304289937
Manufacturer APC
Availability Y
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Design
PDU typesMetered
MountingVertical
Product colourBlack
CertificationEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Rack capacity0U
Ports & interfaces
Power plugIEC309
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
Output connections30 x IEC 320 C13 12 x IEC 320 C19
Features
LED indicatorsYes
Cable length1.83 m
CertificationEN 55022 A,EN 55024, EN 61000-3-2, EN 61000-3-3, FCC 15 A, ICES-003, VCCI A, VDE REACH: No SVHCs
Management features
MonitoringCurrent, Power, Voltage
Ergonomics
LED indicatorsYes
Cable length1.83 m
Power
Maximum power22000 W
Nominal input voltage400 V
Maximum current32 A
Nominal output voltage230 V
Load capacity22080 VA
Maximum input current per phase32 A
Power protection featuresOverload
AC input frequency50 - 60 Hz
Weight & dimensions
Weight8.72 kg
Width56 mm
Depth51 mm
Height1829 mm
Package width170 mm
Package depth112 mm
Package height2050 mm
Package weight11.6 kg
Packaging data
Package width170 mm
Package depth112 mm
Package height2050 mm
Package weight11.6 kg
Operational conditions
Operating temperature (T-T)0 - 55 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating altitude0 - 3000 m
Non-operating altitude0 - 15000 m
Technical details
Total carbon footprint (kg of CO2e)57837.86
Compliance certificatesRoHS

You may also be interested in

Compare Products
Product APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord APC NetShelter Metered Rack PDU, 0U, 3...
$3,211.67
APC NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309 APC NetShelter Rack PDU Advanced, Mete...
$2,916.41
Eaton EVMAF116A power distribution unit (PDU) 24 AC outlet(s) 22.5U Black Eaton EVMAF116A power distribution uni...
$2,672.82
SKU
AP8886
APDU10350ME
EVMAF116A
Description
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
EATON PDU G4 MA, 0U, 1PHASE 16A IEC 309, 12XC13:12XC39 VERTICAL MANAGED G4 SERIES
Short Description
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
NetShelter Rack PDU Advanced, Metered, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 48 Outlets, IEC309
Managed G4 Rack PDU, 22.5U, 3.7 kW, 16 A, 12xC13, 12xC39, 3 m cord
Manufacturer
APC
APC
EATON