Description
|
APC Basic Rack PDU , Input: 230V , Input Connections: IEC-320 C20 , Cord Length: 10 feet ( 3.05 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19. Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit.
|
The Eaton HotSwap Maintenance Bypass enhances availability by providing service continuity in all situations.
Ideal for maintenance and UPS upgrades, the HotSwap MBP facilitates hot-swappable battery replacement from the front panel, with no need to remove the UPS from the rack. Gain ultimate peace of mind that high availability and critical operations will never be compromised during battery replacement or other upgrades. The HotSwap MBP offers 5-15R and 5-20R receptacles.
Features and Benefits
- Enables additional receptacles on the Eaton 5130, 9130, Evolution, Evolution S and EX UPSs for convenient, reliable power distribution - Eases installation with unparalleled flexibility, including a variety of mounting options: rear panel, top, left or right of the UPS (depending on the model) - Provides service continuity during battery replacement, UPS maintenance or upgrade
|
Description: APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19 Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual Output Voltage(s) (main only) - 120, 208, 230 V
Maximum Total Current Draw per Phase - 16 A
Output Connections - (10)IEC 320 C13; (2)IEC 320 C19
Always on Outlets - 12 Overload Protection Input: Nominal input voltage - 120, 208, 230
Input frequency (Hz) - 50/60 Hz
Input Connection Type - IEC-320 C20
Cord Length 8.2 feet ( 2.5 meters ) Acceptable Input Voltage - 90-250 VAC
Maximum Line Current per phase - 16.0 A
Maximum Input Current per phase - 16.0 A
Load Capacity - 3680
|
Features: Single input power source Toolless Mounting Capabilities Vertical Mounting Capabilities
|
Toolless Rack Mounting Capabilities
Server cases do not require additional tools to mount into NetShelter Enclosures, which allows the users to quickly and easily mount units in the rear of the enclosure.
Vertical Mounting Capabilities
Easily mounts vertically in racks or enclosures and occupies zero U of valuable rack space, which allows more equipment in the rack. Units that mount vertically are optimized to fit in a NetShelter enclosures.
Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
|
Marketing Features
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Local Current Monitoring Display The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
Local and web-based monitoring Status available to customers both in the data center and remotely.
Availability
Alarm Thresholds Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
Integrates with StruxureWare Data Center Expert An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.
Load indicator LED Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Flash Upgradeable Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Remote Management Capabilities Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
Agility
Rack-Mountable Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
Single input power source Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
Wide range of input and output connections Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
|
Short Description
|
Rack PDU,Basic, Zero U, 16A, 230V, (20) C13 & (4) C19; IEC C20
|
HotSwap Maintenance ByPass 6000i, For Eaton 9SX/9PX UPS 5/6kVA
|
Rack PDU,Basic, 1U, 16A,208&230V, (10)C13 & (2)C19
|
Rack PDU, Basic, Zero U, 32A, 230V, (20)C13 & (4)C19
|
200V, 208V, 230V, 47 - 63 Hz, IEC-320 C14, 3.05 m, 200-250VAC, 10A, 1245 x 56 x 44 mm, 3.07 kg
|
208/230 V, 8x IEC 320 C13, IEC-320 C20, 1U, 444 x 102 x 44 mm, 1740 g
|