APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black

SKU
AP9559
$611.36
In stock
Only 9 left
Rack PDU,Basic, 1U, 16A,208&230V, (10)C13 & (2)C19
Estimate Fees
For corporate price, please request for quotation at sales@techfable.com.au
More Information
SKU AP9559
EAN 0731304123521
Manufacturer APC
Availability Y
Description:

APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19

Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities

Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual


Output Voltage(s) (main only) - 120, 208, 230 V

Maximum Total Current Draw per Phase - 16 A

Output Connections - (10)IEC 320 C13; (2)IEC 320 C19

Always on Outlets - 12
Overload Protection

Input:

Nominal input voltage - 120, 208, 230

Input frequency (Hz) - 50/60 Hz

Input Connection Type - IEC-320 C20

Cord Length 8.2 feet ( 2.5 meters )

Acceptable Input Voltage - 90-250 VAC

Maximum Line Current per phase - 16.0 A

Maximum Input Current per phase - 16.0 A

Load Capacity - 3680

Design
TypeSingle-phase
PDU typesBasic
MountingHorizontal/Vertical
Product colourBlack
Rack capacity0U/1U
Ports & interfaces
Power plugC20 coupler
AC outlets quantity12 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler
I/O portsOutput Connections - (10)IEC 320 C13; (2)IEC 320 C19 Input Connection Type - IEC-320 C20
Features
Cable length2.5 m
Ergonomics
Cable length2.5 m
Power
Maximum power3680 W
Load capacity3680 VA
Maximum input current per phase16 A
Weight & dimensions
Dimensions (WxDxH)447 x 57.2 x 44.5 mm
Weight980 g
Width447 mm
Depth57.2 mm
Height44.5 mm
Operational conditions
Operating temperature (T-T)0 - 45 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)0 - 95%
Operating relative humidity (H-H)0 - 95%

You may also be interested in

Compare Products
Product APC RACK PDU BASIC 1 U 16A 230V power distribution unit (PDU) 12 AC outlet(s) 0U/1U Black
Hot Product
APC RACK PDU BASIC 1 U 16A 230V power...
$611.36
Eaton HotSwap MBP 6000i power distribution unit (PDU) Black
Bestseller
Eaton HotSwap MBP 6000i power distribu...
$832.57
APC Basic Rack PDU power distribution unit (PDU) 24 AC outlet(s) 0U Black APC Basic Rack PDU power distribution...
$662.20
APC RACK PDU. BASIC. ZERO U. 32A. 230V. (20)C13 & (4)C19 power distribution unit (PDU) 24 AC outlet(s) 0U Black APC RACK PDU. BASIC. ZERO U. 32A. 230V...
$732.06
APC AP7821B power distribution unit (PDU) 8 AC outlet(s) 0U/1U Black APC AP7821B power distribution unit (P...
$889.24
CyberPower PDU41005 power distribution unit (PDU) 8 AC outlet(s) 1U Black CyberPower PDU41005 power distribution...
$684.67
SKU
AP9559
MBP6KI
AP7552
AP7553
AP7821B
PDU41005
Description
Description:

APC Basic Rack PDU, Input : 120, 208, 230V , Input Connection Type : IEC-320 C20 , Cord Length : 8.2 feet ( 2.5 meters ) , Output : 120, 208, 230V , Output Connections : (10)IEC 320 C13, (2)IEC 320 C19

Features: 19 inch Rack-Mountable, Low Cost Power Distribution, Vertical Mounting Capabilities

Includes: Cord Retention Clips, Rack Mounting Brackets, User Manual


Output Voltage(s) (main only) - 120, 208, 230 V

Maximum Total Current Draw per Phase - 16 A

Output Connections - (10)IEC 320 C13; (2)IEC 320 C19

Always on Outlets - 12
Overload Protection

Input:

Nominal input voltage - 120, 208, 230

Input frequency (Hz) - 50/60 Hz

Input Connection Type - IEC-320 C20

Cord Length 8.2 feet ( 2.5 meters )

Acceptable Input Voltage - 90-250 VAC

Maximum Line Current per phase - 16.0 A

Maximum Input Current per phase - 16.0 A

Load Capacity - 3680

The Eaton HotSwap Maintenance Bypass enhances availability by providing service continuity in all situations.

Ideal for maintenance and UPS upgrades, the HotSwap MBP facilitates hot-swappable battery replacement from the front panel, with no need to remove the UPS from the rack. Gain ultimate peace of mind that high availability and critical operations will never be compromised during battery replacement or other upgrades. The HotSwap MBP offers 5-15R and 5-20R receptacles.

Features and Benefits

- Enables additional receptacles on the Eaton 5130, 9130, Evolution, Evolution S and EX UPSs for convenient, reliable power distribution
- Eases installation with unparalleled flexibility, including a variety of mounting options: rear panel, top, left or right of the UPS (depending on the model)
- Provides service continuity during battery replacement, UPS maintenance or upgrade
APC Basic Rack PDU , Input: 230V , Input Connections: IEC-320 C20 , Cord Length: 10 feet ( 3.05 meters ) , Output: 230V , Output Connections: IEC 320 C13,IEC 320 C19.

Includes: Installation guide, Rack Mounting brackets, Toolless Mounting Kit.
Features:
Single input power source
Toolless Mounting Capabilities
Vertical Mounting Capabilities
Marketing Features

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Local and web-based monitoring
Status available to customers both in the data center and remotely.

Availability

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Agility

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Wide range of input and output connections
Product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
CyberPower PDU41005 Switched series power distribution unit provides output from a UPS unit, generator, or utility power to multiple connected devices in datacenter environments. The unit supports remote individual outlet control over the network, allowing administrators to turn on/off connected devices from any location. Administrators can further determine the power sequence used to turn individual outlets on or off.

The power management web interface offers real-time remote monitoring of the PDU vitals of the outlets of networked clients. Event logging via a web browser or network connection allows users to review a history of power conditions. When specified power events occur, automatic event notifications will be sent via email, SMS text, or SNMP trap to designated users so that they can take immediate actions. The featured RJ45 port enables the connection of the optional environmental sensor (ENVIROSENSOR), which can provide real-time temperature and humidity monitoring in an IT center.

The product is also certified to be interoperable and compatible with Cisco Compatible™ network environments, which helps to achieve the best energy performance possible in the datacenter scenario.
Short Description
Rack PDU,Basic, 1U, 16A,208&230V, (10)C13 & (2)C19
HotSwap Maintenance ByPass 6000i, For Eaton 9SX/9PX UPS 5/6kVA
Rack PDU,Basic, Zero U, 16A, 230V, (20) C13 & (4) C19; IEC C20
Rack PDU, Basic, Zero U, 32A, 230V, (20)C13 & (4)C19
208/230 V, 8x IEC 320 C13, IEC-320 C20, 1U, 444 x 102 x 44 mm, 1740 g
Switched, 8 x C13 Out
Manufacturer
APC
EATON
APC
APC
APC
CyberPower